Features & Benefits
Innovative Covering with Tri-Layered Microstructure Designed to Maintain Long-Term Vessel Patency
NOVEL-SPUN INNER GRAFT LAYER
Reduces fibrin deposition and thrombus formation without coatings or drugs.1
CELL-IMPERMEABLE MIDDLE LAYER*
Prevents transmural cellular migration and tissue accumulation.
* Based upon evaluation of the device in an ovine external iliac artery model
Cross-Sectional Histology Images: Left External Iliac, Animal, 180 days. Dolmatch, et al. JVIR. 2020; 31: 494–502. Evaluation of a Novel Spun Polytetrafluoroethylene Stent Graft in an Ovine External Iliac Artery Model (ref 2)
BIOCOMPATIBLE ePTFE OUTER LAYER
Designed to allow tissue ingrowth to prevent endoprosthesis migration.
Representation of the outer ePTFE on the left, and tissue ingrowth on the right
OPTIMIZED RADIAL STRENGTH AND COMPRESSION RESISTANCE
The WRAPSODY CIE has consistent radial strength and robust local compression resistance across all diameter sizes, allowing the WRAPSODY CIE to withstand both intraluminal forces as well as extrinsic pressures placed on the device.1
WRAPSODY CIE versus 10 mm leading covered stent, each compressed by 1.8 N.
SOFTENED END ROWS
The WRAPSODY CIE has end rows with less radial force designed to better conform to healthy vessel tissue, prevent vessel trauma, and improve long-term patency.
1) Softened End Rows with less radial force.1
2) Nitinol Struts allow for upsizing of up to 25% for superior vessel conformance.1
CLINICAL EVIDENCE
“The six-month efficacy data is compelling and provides clinicians the chance to evaluate how WRAPSODY can help us prolong the vascular access of our patients. WRAPSODY should be the new standard of care for these patients.”
– Mahmood K. Razavi, MD, FSIR, FSVM, Interventional Radiologist and Medical Director of Clinical Research at St. Joseph Heart and Vascular Center in Orange, Calif., and Co-Principal Investigator of the WAVE trial.
PINPOINT ACCURACY
1 – Racheted Deployment Handle
for one-handed accurate and controlled WRAPSODY CIE placement
2 – Single Port
for flushing guide wire lumen and WRAPSODY CIE pod
3 – Safety Clip
to prevent inadvertent deployment
4 – Radiopaque Marker Bands
for enhanced visualization
5 – Soft Atraumatic Tip
for a seamless transition over a 0.035″ guide wire
HYDROPHILIC COATING
Allows smooth insertion & withdrawal, along with exceptional trackability
REFERENCES
1. Data on file.
2. Dolmatch et al. 2020. “Evaluation of a Novel Spun Polytetrafluoroethylene Stent Graft in an Ovine External Iliac Artery Model.” Journal of Vascular and Interventional Radiology 21, no. 3 (March): 494-502. doi.org10.1016/j.jvir.2019.07.036. (PMID: 31959517)
3. Razavi. “Six-month safety and efficacy outcomes from the randomized-controlled arm of the WRAPSODY® Arteriovenous Access Efficacy (WAVE) trial”. PowerPoint presented at the annual Cardiovascular and Interventional Radiological Society of Europe (CIRSE) scientific symposium, Lisbon, Portugal, September, 2024.
4. Razavi. “Six-month safety and efficacy outcomes from the WRAPSODY® Arteriovenous Access Efficacy (WAVE) trial”. PowerPoint presented at the annual VEITH symposium, November, 2024.
Order Information
Note: Robust Size Range Available, Including 14 mm and 16 mm Diameter Sizes that are Unique to Merit Medical
409072001_001 ID 121924