ReSolve ConvertX® Nephroureteral & Biliary Stent System

Request Information
ReSolve ConvertX Biliary & Nephroureteral Stent System

DRAIN TO STENT IN 30 SECONDS*

Designed to treat biliary and ureteral obstructions. Place it like any internal-external drain. Convert it to a stent when you are ready.

Video Gallery

ReSolve ConvertX - Drain to Stent in 30 seconds

Introduction to the ReSolve ConvertX Stent System

Introduction to the ReSolve ConvertX Stent System

First Impressions of the ReSolve ConvertX

First Impressions of the ReSolve ConvertX Stent System

Features & Benefits

BILIARY STENT SYSTEM: FIRST PLASTIC BILIARY STENT DESIGNED FOR INTERVENTIONAL RADIOLOGISTS

 

DRAIN TO STENT IN 30 SECONDS*

ReSolve ConvertX - Stent to Drain Conversion


TEAM APPROACH

The internalized plastic stent is designed to be easily removed or exchanged by a gastroenterologist.

BOOST PRODUCTIVITY

Time-consuming reinterventions caused by accidental catheter dislodgement are eliminated.

ENHANCE PATIENT CARE

Designed to improve patient care by eliminating the need for an uncomfortable external drainage bag.


Releasable Drainage Catheter
• Length: 30 cm
• Diameter: 10F
Releasable Drainage Catheter Length

 

Stent
• Length: 5 cm, 7 cm, 10 cm, or 15 cm
• Diameter: 10F
Stent Length

PLASTIC STENTS
— #1 —
Recommended Treatment
Per ACR guidelines for 8 of 9
biliary obstructions1


NEPHROURETERAL STENT SYSTEM: DRAIN TO STENT IN 30 SECONDS*

 

FLEXIBILITY OF TREATMENT

Place it like a nephroureteral drain. Convert it to a ureteral stent when you are ready.
ConvertX Ureteral Stent System - Drain to Stent in 30 Seconds


Releasable Drainage Catheter
• Length: 20 cm or 30 cm
• Diameter: 10F

Stent
• Length: Sizes from 10 cm to 28 cm
• Distal Stent Diameter: 8F or 10F

UNIQUE SOLUTION

Nephroureteral drain and ureteral stent combined into one streamlined product.

BOOSTS PRODUCTIVITY

Conversion takes less than 30 seconds*, and no sterile prep is required.

ENHANCES PATIENT CARE

Patient gains freedom from an external drain without the discomforts of a second invasive procedure.


REFERENCES:
1. American College of Radiology. ACR Appropriateness Criteria®: Radiological Management of Biliary Obstruction. Available at: https://acsearch.acr.org/docs/69344/Narrative/. Accessed March 6, 2019.
* Data on File.

Documents

Discover more about the ConvertX Stent System by reviewing the brochures and Instructions for Use.

Current IFUs

Current Brochures

Order Information

View All Details
Catalog NumberCatheter French Size(F)Tapered Size(F)Catheter Working Length(cm)Stent LengthStent TypeMaximum Guide WireSterilizationLatex FreeHCPCS CodeShipping Box Qty
RCX10-10-03810.3F20 cm10 cmNephroureteral0.038" (0.97 mm)ETOYesC26171
RCX10-8-03810.3F8.3F20 cm10 cmNephroureteral0.038" (0.97 mm)ETOYesC26171
RCX12-10-03810.3F20 cm12 cmNephroureteral0.038" (0.97 mm)ETOYesC26171
RCX12-8-03810.3F8.3F20 cm12 cmNephroureteral0.038" (0.97 mm)ETOYesC26171
RCX14-10-03810.3F20 cm14 cmNephroureteral0.038" (0.97 mm)ETOYesC26171
RCX14-8-03810.3F8.3F20 cm14 cmNephroureteral0.038" (0.97 mm)ETOYesC26171
RCX20-10-03810.3F30 cm20 cmNephroureteral0.038" (0.97 mm)ETOYesC26171
RCX20-8-03810.3F8.3F30 cm20 cmNephroureteral0.038" (0.97 mm)ETOYesC26171
RCX22-10-03810.3F30 cm22 cmNephroureteral0.038" (0.97 mm)ETOYesC26171
RCX22-8-03810.3F8.3F30 cm22 cmNephroureteral0.038" (0.97 mm)ETOYesC26171
RCX24-10-03810.3F30 cm24 cmNephroureteral0.038" (0.97 mm)ETOYesC26171
RCX24-8-03810.3F8.3F30 cm24 cmNephroureteral0.038" (0.97 mm)ETOYesC26171
RCX26-10-03810.3F30 cm26 cmNephroureteral0.038" (0.97 mm)ETOYesC26171
RCX26-8-03810.3F8.3F30 cm26 cmNephroureteral0.038" (0.97 mm)ETOYesC26171
RCX28-10-03810.3F30 cm28 cmNephroureteral0.038" (0.97 mm)ETOYesC26171
RCX28-8-03810.3F8.3F30 cm28 cmNephroureteral0.038" (0.97 mm)ETOYesC26171
RCXB10-10-03810.3F30 cm10 cmBiliary0.038" (0.97 mm)ETOYesC26171
RCXB15-10-03810.3F30 cm15 cmBiliary0.038" (0.97 mm)ETOYesC26171
RCXB5-10-03810.3F30 cm5 cmBiliary0.038" (0.97 mm)ETOYesC26171
RCXB7-10-03810.3F30 cm7 cmBiliary0.038" (0.97 mm)ETOYesC26171
logo